dc.description.abstract | Introducción: El centro Estomatológico Universitario Luis Vallejos Santoni recibe una gran
cantidad de pacientes quienes presentan diferentes condiciones de salud. El monitoreo de las líneas
de agua debería estar involucrada dentro de las normas de bioseguridad y protocolos con los cuales
trabaja la clínica, ya que el agua tiene contacto directo con las mucosas, fluidos orales y estructuras
dentarias del individuo que será tratado. Objetivo: Cuantificar las bacterias que fueran halladas en
el agua de las unidades dentales del Centro Estomatológico Universitario Luis Vallejos Santoni.
Materiales y métodos: se realizó un muestreo en el Centro Estomatológico Universitario Luis
Vallejos Santoni, recolectando 1 muestra de la red de abastecimiento, 1 muestra del suministro de
agua de caño (una vez usado el ozonificador) y 28 muestras de las jeringas triples de las unidades
dentales, teniendo un total 30 muestras de agua. Según los parámetros del reglamento de la calidad
de agua, se hizo el recuento de bacterias heterotróficas, coliformes totales, coliformes
termotolerantes y Escherichia coli utilizando el método de filtración por membrana y tubos
múltiples. El análisis de las muestras de llevo a cabo en el Laboratorio de Aguas del Centro de
Salud CLAS Anta. Resultados: se observó que sólo existe crecimiento bacteriano a nivel de las
muestras que corresponden a las de las unidades dentales habiendo una mayor incidencia en el
crecimiento de Bacterias heterotróficas mostrando que el 86.7% exceden los límites máximos
permisibles y el 13.3% están por debajo de los límites máximos permisibles llegando a cuantificar
un total de 163331 UFC/100ml; y teniendo como resultados para Coliformes totales
30.2NMP/100ml; para Coliformes termotolerantes o fecales 3.3 NMP/100ml y para Escherichia
Coli <1.1 NMP/100ml. Conclusiones: podemos afirmar que las muestras de red de abastecimiento
y de suministro de agua de caño cumplen con los parámetros del reglamento de calidad de agua
según DS 031-2010-SA MINSA, ya que ambas muestran 10UFC/100ml y 21UFC/100ml
respectivamente, por el contrario 26 de las muestras de agua de las unidades dentales exceden los
límites máximos permisibles <500UFC100ml. | es_PE |
dc.description.abstract | Introduction: The Luis Vallejos Santoni University Stomatological Center receives a very large
number of patients who present different health conditions. The monitoring of the water lines
should be involved within the biosecurity norms and protocols with which the clinic works, since
the water has direct contact with the mucous membranes, oral fluids and dental structures of the
individual to be treated. Target: To quantify the bacteria that werw found in the water of the dental
units of the Luis Vallejos Santoni University Stomatological Center. Materials and methods: a
sampling was performed at the Luis Vallejos Santoni University Stomatological Center, collecting
1 sample from the water supply network, 1 sample from the pipe water supply (once the ozonator
was used) and 28 samples from the triple syringes of the dental units, for a total of 30 water
simples. Accordingto the parameters of the water quality regulations Heterotrophic bacteria, totales
coliforms, thermotolerant coliforms and Escherichia coli were counted using membrane filtration
and multiple tubes methods. The analysis of the samples carried out in the Water Laboratory of the
CLAS Anta Health Center. Results: it was demonstrated that there is only bacterial growth at the
level of the samples that correspond to the dental units, having a higher incidence in the growth of
heterotrophic bacteria, showing that 86.7% exceed the maximum permissible limits and 13.3% are
below the limits. maximum allowable reaching a total of 163331 CFU/100ml; and having as results
for total coliforms 30.2 NMP/100ml; for thermotolerant or faecal coliforms 3.3 NMP/100ml and
for Escherichia Coli <1.1 NMP/100ml. Conclusions: we can affirm that the samples of the supply
network and of the tap water supply comply with the parameters of the water quality regulation
according to DS 031-2010-SA MINSA, since both show 10UFC/100ml and 21UFC/100ml,
respectively. on the contrary, 26 of the water samples from the dental units exceed the maximum
permissible limits <500UFC100ml. | en_US |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Andina del Cusco | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | es_PE |
dc.subject | Agua | es_PE |
dc.subject | Unidad dental | es_PE |
dc.subject | Crecimiento bacteriano | es_PE |
dc.subject | Bacterias heterotróficas | es_PE |
dc.title | Recuento bacteriológico del agua de las unidades dentales del Centro Estomatológico Universitario Luis Vallejos Santoni, Cusco, 2022 | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.name | Cirujana Dentista | es_PE |
thesis.degree.grantor | Universidad Andina del Cusco. Facultad de Ciencias de la Salud | es_PE |
thesis.degree.discipline | Estomatología | es_PE |
dc.publisher.country | PE | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#3.02.14 | es_PE |
renati.advisor.dni | 23990092 | |
renati.advisor.orcid | https://orcid.org/0000-0003-2909-0620 | es_PE |
renati.author.dni | 70280421 | |
renati.discipline | 911016 | es_PE |
renati.juror | Pletickosich Picón, Alejandro Pablo | |
renati.juror | Cabrera Cuentas, Rocio | |
renati.juror | Malpartida Caviedes, Annushka | |
renati.juror | Valer Contreras, Aida | |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |
dc.description.lineadeinvestigacion | Promoción de la Salud y Prevención de enfermedades estomatológicas | es_PE |