dc.description.abstract | Objetivo: El presente trabajo de investigación tuvo como objetivo Analizar
la calidad del diseño de la prótesis parcial en modelos de estudio inferior
clase I Kennedy realizados por los cirujanos dentistas del distrito del Cusco,
2022.
Material y métodos: El presente trabajo de investigación tiene un enfoque
cuantitativo, alcance descriptivo, investigación básica de tipo prospectivo,
transversal, observacional y de campo, la población estuvo constituida por
cirujanos dentistas que laboran en consultorios, centros y clínicas
registrados en RENIPRES, la muestra estuvo constituida por 263 cirujanos
dentistas el tipo de muestreo fue no probabilístico, la técnica de la
investigación fue observacional, el instrumento que se utilizó fue la ficha de
recolección de datos donde se registró la calidad de diseño de la prótesis
parcial clase I de Kennedy inferior el cual fue registrada como deficiente,
regular y adecuado según el diseño de los componentes de la prótesis
parcial removible en correcto e incorrecto utilizando una ficha técnica; se
realizó una estadística descriptiva de las variables de estudio utilizando
frecuencias y porcentajes.
Resultados: La calidad de diseño de prótesis parcial removible fue
deficiente (44.9%), regular (31.9%), adecuado (23.2%). Según sus
componentes la calidad de diseño de los apoyos oclusales fue incorrecto
(55.9%), de los retenedores incorrecto (61.2%), los conectores menores
fueron incorrecto (57.8%), los conectores mayores fueron incorrecto
(64.3%), de las retenciones para bases de acrílico y extensión de las bases
de las prótesis fue incorrecto (63.5%).
Conclusiones: La calidad de diseño de prótesis parcial removible fue
deficiente en los cirujanos dentistas de la ciudad del Cusco, y la calidad de
diseño de los componentes fue incorrecto en su mayor porcentaje. | es_PE |
dc.description.abstract | Objective: The present research work aimed to analyze the quality of the
design of the partial prosthesis in lower study models class I Kennedy
performed by dental surgeons in the district of Cusco, 2022.
Material and methods: The present research work has a quantitative
approach, descriptive scope, basic research of prospective, cross-sectional,
observational and field type, the population was constituted by dental
surgeons who work in offices, centers and clinics registered in RENIPRES,
the sample was constituted by 263 dental surgeons the type of sampling
was non-probabilistic, the research technique was observational, the
instrument that was used was the data collection sheet where the design
quality of the lower Kennedy class I partial prosthesis was recorded, which
was registered as deficient, regular and adequate according to the design
of the components of the removable partial prosthesis in correct and
incorrect using a technical sheet; Descriptive statistics of the study variables
were performed using frequencies and percentages.
Results: The design quality of removable partial prosthesis was poor
(44.9%), fair (31.9%), adequate (23.2%). According to its components, the
design quality of the occlusal supports was incorrect (55.9%), of the
retainers incorrect (61.2%), the minor connectors were incorrect (57.8%),
the major connectors were incorrect (64.3%), of the retentions for acrylic
bases and extension of the bases of the prostheses was incorrect (63.5%).
Conclusions: The design quality of removable partial prosthesis was
deficient in dental surgeons in the city of Cusco, and the design quality of
the components was incorrect in its highest percentage. | en_US |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Andina del Cusco | es_PE |
dc.rights | info:eu-repo/semantics/restrictedAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | es_PE |
dc.subject | Calidad de sueño | es_PE |
dc.subject | Prótesis dental | es_PE |
dc.title | Calidad del diseño de prótesis parcial removible en modelos de estudio inferior con clase I de Kennedy realizados por cirujanos dentistas, Cusco 2022 | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.name | Cirujana Dentista | es_PE |
thesis.degree.grantor | Universidad Andina del Cusco. Facultad de Ciencias de la Salud | es_PE |
thesis.degree.discipline | Estomatología | es_PE |
dc.publisher.country | PE | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#3.02.14 | es_PE |
renati.advisor.dni | 40975702 | |
renati.advisor.orcid | https://orcid.org/0000-0002-1299-7907 | es_PE |
renati.author.dni | 47551413 | |
renati.discipline | 911016 | es_PE |
renati.juror | Gamero Huarcaya, Valery Kimiyo | |
renati.juror | Gutierrez Acuña, Yeni | |
renati.juror | Lazo Álvarez, Julio | |
renati.juror | Tipian Tasayco, Martin Wilfredo | |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |