dc.description.abstractEn los últimos años los investigadores en el área de la ingeniería sismoresistente fueron evaluando las normas e innovando nuevos parámetros, los cuales brindaran una mejor respuesta frente a los sismos que pudieran ocurrir, en el caso de los parámetros que encontramos en la Norma Técnica Peruana para el análisis de Tanques elevados se puede verificar que las investigaciones no profundizaron en el tema, siendo; estos últimos, estructuras de uso esencial para la sociedad, debido al uso diario de los servicios básicos. La Norma ACI-350 de Estados Unidos presenta una alternativa diferente, la cual cuenta con diferentes parámetros de solución frente al análisis que se desea evaluar. Se realizó una investigación de tanques elevados de configuración octogonal frente a una rectangular evaluándolos con las normas NTP. E.030 y la ACI-350 en el distrito de San Sebastian – Alto Qosqo de la ciudad del Cusco. Se evaluaran los parámetros relacionados a la Norma Técnica Peruana E.030 sismo resistente en relación a las normas ACI-350 presentando indicadores similares, con los cuales se realizara posteriormente un análisis sismoresistente permitiendo elaborar el espectro de respuesta correspondiente a las normas investigadas, se realizara un análisis hidrodinámico para cada configuración estructural de tanque elevado, determinando cuál de ellos presenta un mejor desempeño frente a la acción de un sismo. Dentro del análisis de datos se evaluaran momentos cortantes, flectores, fuerzas axiales y desplazamientos que desarrollaran ambas construcciones mediante un análisis dinámico. Finalmente se culminara con la discusión, conclusiones y las recomendaciones.es_PE
dc.description.abstractIn recent years researchers in the area of seismic engineering were evaluating the standards and innovating new parameters that would provide a better response to earthquakes that could occur, in the case of parameters found in the Peruvian Technical Standard for Analysis of elevated tanks can verify that the investigations did not deepen in the subject being structures of essential use for the society, due to the daily use of the basic services. The ACI-350 of the United States presents an alternative proposal which has different parameters of solution against the analysis that is wanted to be carried out, an investigation of elevated tanks of octagonal configuration against a rectangular one was realized evaluating them with the norms NTP. E.030 and ACI-350 in the district of San Sebastian - Alto Qosqo of the city of Cusco. The parameters related to the Peruvian Technical Standard E.030 resistant earthquake will be evaluated in relation to the ACI-350 standards, which present similar parameters, with which a seismic-resistant analysis will be carried out, allowing the construction of the response spectrum corresponding to the standards Investigated, a hydrodynamic analysis will be performed for each structural configuration of octagonal and rectangular elevated tank which will provide better performance against the action of an earthquake. Within the analysis of data we will evaluate cutting moments, bending, axial forces and displacements that would develop our essential building through an essential dynamic analysis will finally culminate in the discussion, conclusions and recommendations.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Andina del Cuscoes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.5/pe/es_PE
dc.sourceUniversidad Andina del Cuscoes_PE
dc.sourceRepositorio Institucional - UACes_PE
dc.subjectIngeniería-Sismorresistentees_PE
dc.subjectParámetroses_PE
dc.subjectTanques elevadoses_PE
dc.subjectAnálisis dinámicoes_PE
dc.titleEvaluación comparativa de la respuesta estructural mediante un análisis hidrodinámico de un tanque elevado de sección octogonal frente a uno rectangular en el proyecto de saneamiento Alto Qosqo-Cusco.es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.grantorUniversidad Andina del Cusco. Facultad de Ingeniería y Arquitecturaes_PE
thesis.degree.levelTitulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE