Show simple item record

dc.contributor.advisorSoto Florez, Heiner
dc.contributor.authorVergara Mujica, Rodrigo
dc.date.accessioned2017-10-09T14:31:02Z
dc.date.available2017-10-09T14:31:02Z
dc.date.issued2017-06-16
dc.identifier.urihttps://hdl.handle.net/20.500.12557/957
dc.description.abstractRESUMEN La presente investigación estudio y comparo la respuesta sísmica de cinco modelos con diferentes consideraciones de restricción en la base de una edificación de uso multifamiliar empleando un modelo de interacción suelo – estructura (ISE) prescrito por la norma rusa SNIP 2.02.05 - 87 y la aplicación de un sistema de aislación sísmica compuesto por dispositivos elastoméricos con núcleo de plomo (LRB). Para un modelo se usó un análisis modal espectral con base fija (Espectro E.030) y los cuatro modelos restantes usaron un análisis tiempo – historia considerando y sin considerar la interacción suelo – estructura (ISE) y el aislamiento de base. La forma en la que se desarrolló esta investigación comenzó por modelar la estructura base sobre la cual se crean los cinco modelos antes mencionados usando el software ETABS 2013. Posteriormente, se procedió a calcular los coeficientes de rigidez y se diseñó el sistema de aislación. Después, se escogieron tres registros sísmicos de 30 en total de la base de datos PEER / NGA WEST 2 que cumplían con todas las características del lugar del proyecto. Luego, se asignaron los valores de restricción obtenidos usando la propiedad Springs al centroide de la platea de cimentación y los dispositivos de aislación sísmica usando la propiedad Link una vez creada la interfaz de aislación sísmica entre el cielo del semisótano y el primer nivel. Como conclusión se puede afirmar que el modelo que presento una mejor respuesta sísmica fue el modelo con aislamiento de base (LRB) y no aquel modelo que considero tanto la interacción suelo – estructura y el aislamiento conjuntamente (ISE + LRB). Este último modelo teniendo una buena respuesta sísmica en términos de desplazamientos máximos, distorsiones de entrepiso y fuerzas cortantes por piso, no la tuvo en términos de fuerzas internas pues en muchos casos presenta los valores máximos en comparación con todos los modelos estudiados. De igual forma, el modelo que considera la interacción suelo – estructura (ISE) presenta desplazamientos máximos y distorsiones de entrepiso grandes que se traducen en la disminución de la fuerza cortante por piso en la dirección X no siendo así para la dirección Y y en términos de fuerzas internas muestra valores máximos en general en fuerzas cortantes y momentos flectores. Por último, el modelo que no considera la interacción suelo – estructura ni el aislamiento de base (SINA), presentó una respuesta sísmica que se podría considerar intermedia con respecto a los modelos estudiados.es_PE
dc.description.abstractThis thesis studied and compared the seismic response of five models with different considerations of restraints in the base of a multifamily building using a model of soil – structure interaction (ISE) standardize by the Russian regulation SNIP 2.02.05 - 87 and the application of a seismic isolation system made of lead rubber bearing devices (LRB). For one model, a modal spectral analysis and fixed base was used (Espectro E.030). The other four models used a time – history analysis both considering and not considering soil – structure interaction (ISE) and base isolation. We initiated this investigation by making a base structure upon which the five aforementioned models are created using the ETABS 2013 software. Then, the stiffness coefficient was calculated and the isolation system was designed. Three seismic responses from a total of 30 were selected from the PEER / NGA WEST 2 data base that comply with all the features of the location of the project. Then, all the values of restraints were assigned to the slab´s centroid using the Spring property and the devices of seismic isolation using the Link property once the isolation interface was created between the basement´s ceiling and the first level. In conclusion, the model that presented the best seismic response was the one that considered the isolation system (LRB) and not the one that considered the soil – structure interaction and the isolation system simultaneously (ISE + LRB). This last model had a good seismic response in terms of maximum displacement, story drifts and shear force by story but not in terms of internal forces; in fact, in many cases in this aspect it presents the highest values compared to all the other models studied. In like manner, the model that considers the soil – structure interaction (ISE) had severe displacement and story drift that are interpreted in the decrease of shear force by story in the X direction but not in the Y direction, and in terms of internal forces this model shows the highest values for shear forces and bending moments. Finally, the model that had neither consideration for soil – structure interaction nor seismic isolation (SINA), presented a seismic response that could be considered as intermediate with regard to the other studied models.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Andina del Cuscoes_PE
dc.rightsinfo:eu-repo/semantics/restrictedAccesses_PE
dc.sourceUniversidad Andina del Cuscoes_PE
dc.sourceRepositorio Institucional - UACes_PE
dc.subjectInteracción-Sueloes_PE
dc.subjectCoeficientes-Rigidézes_PE
dc.subjectAislación sismicaes_PE
dc.subjectRespuesta sísmicaes_PE
dc.titleAnálisis comparativo de la respuesta sísmica de una edificación de 8 niveles aplicando el modelo dinámico interacción suelo - estructura prescrito por la Norma Rusa usando un sistema de aislación basal elastomérico con núcleo de plomo (LRB) y empleando un análisis dinámico tiempo-historia. Caso: residencial "El Zorzal".es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.grantorUniversidad Andina del Cusco. Facultad de Ingeniería y Arquitecturaes_PE
thesis.degree.levelTitulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE


Files in this item