dc.description.abstractEsta investigación está enfocada en la determinación del comportamiento de medición de volúmenes de los medidores utilizados en el parque de medidores de la ciudad del Cusco, evaluándolos en condiciones de inclinación. La instalación inclinada de un medidor es muy recurrente en la mayoría de casos por diferentes factores como es la topografía de la zona, la posición de la matriz de agua potable con respecto a la acometida domiciliaria, la maniobrabilidad del operario y otros. La Norma Metrológica Peruana 005-2011 estipula que no se debe exceder en 5° en la inclinación del medidor ya que este podría generar errores de medición. Es por ello que se evaluó los medidores en laboratorio con niveles de inclinación de 5%, 10%, 15%, 25% y 35% a los medidores de mayor representatividad del parque de medidores sometiéndolos a los caudales de prueba, permanentes (Q3), de transición (Q2) y mínimos (Q1). Los resultados en laboratorio se corroboran con los resultados del trabajo de campo, donde se contrastaron medidores que se encontraban instalados, los cuales tenían un nivel de inclinación dentro de la ciudad del Cusco, con medidores patrón instalados horizontalmente, donde se cuantificó las perdidas por agua no facturada que genera el efecto de la inclinación, lo cual se ve expresado en su facturación mensual, finalmente se evaluó la correlación que existe entre el nivel de inclinación y el error que este genera. De acuerdo a los resultados obtenidos en la investigación y el análisis respectivo, se concluyó que existe una submedición relacionada directamente con la inclinación del medidor, expresado en la correlación negativa entre estas dos variables, en el caudal de transición y el caudal mínimo, mientras que en el caudal permanente existe una relación poco significativa; así mismo se ve reflejado en la facturación mensual, donde los medidores inclinados generan una submedición con respecto al medidor patrón en horizontal donde se evidencia la perdida por agua no facturada.es_PE
dc.description.abstractThis research is focused on determining the behavior of volume measurement of the water flow meters used in Cusco, evaluating them in terms of angle of inclination. Inclined installation of a meter is recurrent in the majority of cases because of factors such as the topography of the area, the position of the array of water with respect to home supply connection, maneuverability of the operator and others. Peruvian Metrological Standard 005-2011 states that they should not exceed 5 ° in the tilt of the meter as this could lead to measurement errors. Therefore, the meters are evaluated in laboratory incline levels of 5%, 10%, 15%, 25% and 35% in the best representation possible of all of the meters used in Cusco, subjecting them to meter flow tests, including permanent flow (Q3) , transition flow (Q2) and minimum flow (Q1). The laboratory results are corroborated by the results of fieldwork, where meters that were installed at an incline within the city of Cusco were contrasted those that were installed horizontally. The losses for the non-billed water due to the incline at which the meters were installed, which is expressed in its monthly billing, were quantified. Finally the correlation between the angle of inclination and the error generated was evaluated. According to the results of research and respective analysis, it was concluded that there is an undermeasurement related directly to the incline of the meter , expressed in the negative correlation between these two variables, the transition flow and minimum flow, while the with the permanent flow there is a relationship of very little significance; likewise it was reflected in the monthly billing, where inclined meters generate an undermeasurement with respect to horizontally installed meters, where the loss is shown in the unbilled water.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Andina del Cuscoes_PE
dc.rightsinfo:eu-repo/semantics/restrictedAccesses_PE
dc.sourceUniversidad Andina del Cuscoes_PE
dc.sourceRepositorio Institucional - UACes_PE
dc.subjectVolúmeneses_PE
dc.subjectMedidoreses_PE
dc.subjectAgua potablees_PE
dc.subjectErrores-Mediciónes_PE
dc.titleDeterminación del error en la medición, de volúmenes, en condiciones de inclinación de los medidores de agua potable utilizados en la ciudad del Cusco.es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.grantorUniversidad Andina del Cusco. Facultad de Ingeniería y Arquitecturaes_PE
thesis.degree.levelTitulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record