dc.description.abstractEn la provincia de La Convención, distrito de Maranura, se observa que la fabricación del concreto estructural f´c 210 kg/ cm2, se realiza con agregado hormigón (canto rodado) y de forma empírica; los dedicados al ámbito de la construcción mencionan que alcanzan resistencias a un f’c 210 kg/cm2, donde no se tiene control de calidad que certifique estos resultados. Para la comprobación de las resistencias que se alcanza con agregado hormigón se replicó la elaboración del concreto que realizan en la zona, donde se obtuvo valores menores af´c 210 kg/ cm2 con promedios de f´c 157.83 kg/ cm2. Por lo tanto, el presente trabajo de investigación tiene como objetivo elaborar un concreto f´c 210 kg/ cm2 con agregado clasificado es decir agregado fino y agregado grueso, apartir de la evaluación de sus propiedades , la comparación con las normas , elección de los álveos que serán evaluados. Para la elección de los álveos que fueron evaluados para la extracción de los agregados, se realizó una ficha de evaluación en in situ de acuerdo a su accesibilidad, años de extracción, comercialización y el tratamiento que se realiza a los agregados; los álveos seleccionados como resultado fueron el álveo Santa María y Paqcha Uchumayo. Se analizó las propiedades físicas, mecánicas (ensayo de desgaste por abrasión, ensayo por durabilidad con sulfato de magnesio) de los agregados según la norma ASTM C-33, que brinda los requisitos generales, donde los dos álveos cumplen con los parámetros establecidos según la norma. Al realizar la elaboración del concreto con agregado clasificado es decir agregado grueso y agregado fino según el método del ACI 211.1 se obtuvo resistencias mayores a f´c 210 kg/ cm2 con promedios de f´c 305.95kg/ cm2 . La dosificación obtenida para un m3 con agregado clasificado es de 8.638 bolsas de cemento, 0.416 de agregado fino, 0.624 m3 de agregado grueso y 0.210 m3 de agua con un costo de 371.50 soles, a comparación de un concreto elaborado con agregado hormigón que es de 6.5 bolsas de cemento, 0.643m3 de agregado hormigón y 0.174 m3 de agua con costo de 286.51.es_PE
dc.description.abstractIn the province of Convención, Maranura district, it is observed that the production of structural concrete f'c 210 kg / cm2, is done with aggregate concrete (rolled) and in an empirical way; those dedicated to the field of construction mention that they reach resistances to a f'c 210 kg / cm 2, where there is no quality control that certifies these results. For the test of the resistance that is reached with aggregate concrete the elaboration of the concrete that carried out in the zone was replicated, where values smaller than f'c 210 kg/ cm2 with averages of f'c 157.83 kg / cm2 were obtained. Therefore, the present research work has as objective to elaborate a concrete f'c 210 kg /cm2 with aggregate classified that is to say fine aggregate and coarse aggregate, from the evaluation of its properties, the comparison with the norms, election of The laves that will be evaluated. For the selection of the laves that were evaluated for the extraction of the aggregates, an evaluation card was made in situ according to its accessibility, years of extraction, commercialization and the treatment that is done to the aggregates; The selected laves were Santa Maria and Paqcha Uchumayo. The physical, mechanical (abrasion wear test, magnesium sulphate durability test) of the aggregates according to ASTM C-33, which provides the general requirements, where the two laves meet the parameters established by rule. When making the concrete with aggregate classified as thick aggregate and fine aggregate according to the method of ACI 211.1, it was obtained resistance greater than f'c 210 kg / cm2 with averages of f'c 305.95 kg / cm2 . The dosage obtained for an m3 with classified aggregate is 8,638 bags of cement, 0.416 of fine aggregate, 0.624 m3 of coarse aggregate and 0.210 m3 of water with a cost of371.50 soles, compared to a concrete made with aggregate concrete that is of 6.5 bags of cement, 0.643m3 of aggregate concrete and 0.174 m3 of water with cost of 286.51.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Andina del Cuscoes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.5/pe/es_PE
dc.sourceUniversidad Andina del Cuscoes_PE
dc.sourceRepositorio Institucional - UACes_PE
dc.subjectResistenciaes_PE
dc.subjectAgregadoses_PE
dc.subjectCompresiónes_PE
dc.subjectPropiedades físicases_PE
dc.titleAnálisis comparativo de la resistencia a la compresión de un concreto F`C 210KG/CM2, elaborado con agregado hormigón y agregado clasificado, en el distrito de Maranura - La Convención - Cusco.es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.grantorUniversidad Andina del Cusco. Facultad de Ingeniería y Arquitecturaes_PE
thesis.degree.levelTitulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess