dc.contributor.advisor | Chacón Sánchez, Víctor | |
dc.contributor.author | Valer Mayorga, Alvaro Alonso | |
dc.contributor.author | Santa Cruz Borda, Jhort Kenvi | |
dc.date.accessioned | 2024-03-22T20:24:42Z | |
dc.date.available | 2024-03-22T20:24:42Z | |
dc.date.issued | 2023-12-19 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12557/6157 | |
dc.description.abstract | La presente tesis de investigación tiene por finalidad mejorar las propiedades físico-mecánicas
del ladrillo industrializado King Kong 18 huecos, optimizando sus propiedades según el clima
frio de nuestra región, se analizaron las características físicas (variación dimensional, alabeo,
succión, absorción y conductividad térmica) y mecánicas (resistencia a la compresión) de
ladrillos de 9cm x 13cm x 24cm, fabricados con arcilla, arena, tierra negra y agua., variando
la dosificación de sus componentes con respecto al ladrillo industrializado tradicional de la
empresa (Arcilla 30% - Arena 50% - Tierra Negra 20%), modificando sus porcentajes de
arcilla y arena correspondientemente, incorporando diferentes porcentajes de arcilla en las
dosificaciones planteadas (Dosificación N°1 a N°5). Estas variaciones se realizaron tomando
como referencia la composición del ladrillo industrializado tradicional de la empresa y la
revisión bibliográfica.
La elaboración y producción de las unidades de albañilería fue llevada a cabo en la empresa
Ladrillos Muralla S.R.L., empleando los equipos, maquinaria industrial y materiales de
mencionada empresa. Las pruebas que se llevaron a cabo en los materiales como
granulometría, límites de Atterberg se realizaron de acuerdo a las especificaciones establecidas
en las normas técnicas peruanas (NTP 400.012-2013 y NTP 339.129.1998). Los ensayos
sometidos a los ladrillos tales como análisis de variación dimensional, alabeo, succión,
absorción, resistencia a la compresión se realizaron de acuerdo a las especificaciones de la
norma técnica peruana (NTP 399.613 2017 UNIDADES DE ALBANILERIA. En general la
NTP.070). Y por último el ensayo de conductividad térmica se realizó de acuerdo a las
especificaciones establecidas en la ASTM C177-13. Habiendo sometido a prueba un total de
120 unidades de albañilería.
En conclusión. Se comprobó que los resultados más favorables lo presentaron las unidades de
albañilería con la dosificación N°5 (+5% de arena), presentando el valor promedio de
conductividad térmica menor de 0.3328 W/(m*°K) y la dosificación tradicional presenta el
valor promedio mayor de resistencia a la compresión 274.1 kg/cm2 y cumpliendo
satisfactoriamente con los demás ensayos según la NTP.070. | es_PE |
dc.description.abstract | The purpose of this research thesis is to enhance the physical and mechanical properties of the
industrialized King Kong 18-hole brick, optimizing its features according to the cold climate
of our region. The study analyzed the physical (dimensional variation, warping, suction,
absorption, and thermal conductivity) and mechanical (compressive strength) characteristics
of bricks measuring 9cm x 13cm x 24cm. These were manufactured using clay, sand, black
soil, and water, with variations in component proportions compared to the traditional
industrialized brick of the company (Clay 30% - Sand 50% - Black Soil 20%). Different
percentages of clay were incorporated in the proposed formulations (Dosage No. 1 to No. 5),
guided by the composition of the traditional industrialized brick and literature review.
The production of masonry units took place at Ladrillos Muralla S.R.L., utilizing the
company's equipment, industrial machinery, and materials. Tests on materials such as
gradation and Atterberg limits followed the specifications of Peruvian technical standards
(NTP 400.012-2013 and NTP 339.129.1998). Tests on bricks, including dimensional
variation, warping, suction, absorption, and compressive strength, were conducted according
to the Peruvian technical standard (NTP 399.613-2017 MASONRY UNITS. Overall,
NTP.070). The thermal conductivity test adhered to ASTM C177-13 specifications, with a
total of 120 masonry units subjected to testing.
In conclusion. It was found that the most favorable results were presented by the masonry
units with dosage No. 5 (+5% sand), presenting the average thermal conductivity value of less
than 0.3328 W/(m*°K) and the traditional dosage presents the highest average value of
compressive strength was 274.1 kg/cm2 and satisfactorily complying with the other tests
according to NTP.070. | en_US |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Andina del Cusco | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | es_PE |
dc.subject | Unidades de albañilería | es_PE |
dc.subject | Dosificación | es_PE |
dc.subject | Propiedades físico-mecánicas | es_PE |
dc.title | Evaluación de la conductividad térmica, propiedades físico-mecánicas del ladrillo King-Kong 18 huecos para diferentes dosificaciones de sus componentes con respecto al ladrillo industrializado del sector Oscollopampa - Cusco 2023. | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.name | Ingeniero Civil | es_PE |
thesis.degree.grantor | Universidad Andina del Cusco. Facultad de Ingeniería y Arquitectura | es_PE |
thesis.degree.discipline | Ingeniería Civil | es_PE |
dc.publisher.country | PE | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.01.01 | es_PE |
renati.advisor.dni | 23807993 | |
renati.advisor.orcid | https://orcid.org/0000-0001-6891-6902 | es_PE |
renati.author.dni | 73953436 | |
renati.author.dni | 70683267 | |
renati.discipline | 732016 | es_PE |
renati.juror | Alvarez Monterola, Walter Roberto | |
renati.juror | Arohuanca Sosa, Rode Luz | |
renati.juror | Gil Rodríguez, Carmen Cecilia | |
renati.juror | Aguilar Huerta, Jose Ronald | |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |