Show simple item record

dc.contributor.advisorChacón Sánchez, Víctor
dc.contributor.authorHerencia Turpo, Paola Milena
dc.contributor.authorPalomino Aroni, Paul Erick
dc.date.accessioned2023-07-04T20:50:25Z
dc.date.available2023-07-04T20:50:25Z
dc.date.issued2023-03-27
dc.identifier.urihttps://hdl.handle.net/20.500.12557/5544
dc.description.abstractEn esta investigación se evaluó los valores de transmitancias térmicas de los módulos habitacionales Sumaq Wasi, los que actualmente son ejecutados por el Programa Nacional de Vivienda Rural (PNVR) en beneficio de los peruanos en condición de pobreza y pobreza extrema. Para la presente investigación se tomaron en cuenta 02 módulos habitacionales existentes en el distrito de Ccatcca, la primera con material predominante de adobe ubicada en la comunidad de Cjatacamara, y la segunda con material predominante de ladrillo ubicada en la comunidad de Ccopi; cada una cuenta con diferentes dimensiones y materiales característicos en sus envolventes, es así como se calculó los valores de transmitancias térmicas de sus respectivas envolventes según los límites máximos de la norma técnica EM. 110 “Confort térmico y lumínico con eficiencia energética” la cual corresponde a la Reglamento Nacional de Edificaciones, con el objetivo de comparar los valores de transmitancias térmicas de ambos módulos Sumaq Wasi. El R.N.E. norma EM. 110 brinda información sobre el procedimiento que se utiliza para hallar las transmitancias térmicas en muros, techos y pisos. Para la presente investigación, elegimos las viviendas ambos tipos de vivienda para hacer toma de datos, mediciones y levantamiento para contrastar con los planos que posteriormente nos brindó el Ministerio de Vivienda; asimismo, se realizó un modelado en el programa Autodesk Revit 2023, posteriormente colocamos los datos de espesor, cantidad, perímetro y coeficiente de transmitancia térmica en las tablas brindadas por la R.N.E. norma EM. 110, para así obtener transmitancias térmicas finales de muros, techos y pisos para cada módulo Sumaq Wasi de adobe con área tapón y doble muro de ladrillo con aislante. Se concluyó que ambos módulos habitacionales Sumaq Wasi cumplen con los límites máximos de la R.N.E. norma EM. 110 a excepción de la envolvente tipo 4A, 4B y 4C del módulo de doble muro de ladrillo con aislante. En el caso del módulo de adobe con área tapón sus transmitancias son en el tipo de envolvente 1A es 1.658 W/m 2 K, en 3A es 0.928 W/m 2 K y en 4A es 0.555 W/m 2 K; y en el módulo de doble muro de ladrillo con aislante en el tipo 1A es 1.813 W/m 2 K, en 3A es 0.926 W/m 2 K y en 4A es 3.417 W/m 2 K, corroborando que el módulo de doble muro de ladrillo con aislante cumple con los límites máximos de la norma en muros y techos, más no en pisos.es_PE
dc.description.abstractThis research evaluated the thermal transmittance values of the Sumaq Wasi housing modules, which are currently implemented by the National Rural Housing Program (PNVR) for the benefit of Peruvians living in poverty and extreme poverty. For the present investigation, two existing housing modules were taken into account in the district of Ccatcca, the first one with predominantly adobe material located in the community of Cjatacamara, and the second one with predominantly brick material located in the community of Ccopi; each one has different dimensions and characteristic materials in their envelopes, thus the values of thermal transmittances of their respective envelopes were calculated according to the maximum limits of the technical standard EM. 110 "Thermal and lighting comfort with energy efficiency", which corresponds to the National Building Regulations, in order to compare the thermal transmittance values of both Sumaq Wasi modules. The R.N.E. norm EM. 110 provides information on the procedure used to find the thermal transmittances in walls, roofs and floors. For the present investigation, we chose the houses and both types of houses to make data collection, measurements and survey to contrast with the plans that were later provided by the Ministry of Housing; also, a modeling was made in the program Autodesk Revit 2023, then we placed the data of thickness, quantity, perimeter and coefficient of thermal transmittance in the tables provided by the R. N.E. norm EM. 110, in order to obtain the final thermal transmittance of walls, roofs and floors for each Sumaq Wasi module of adobe with plug area and double brick wall with insulation. It was concluded that both Sumaq Wasi housing modules comply with the maximum limits of the R.N.E. standard EM. 110 with the exception of the envelope type 4A, 4B and 4C of the double brick wall module with insulation. In the case of the adobe module with plugged area its transmittances are in the envelope type 1A is 1.658 W/m 2 K, in 3A is 0.928 W/m 2 K and in 4A is 0.555 W/m 2 K, and in the double brick wall module with insulation in type 1A is 1.813 2 W/m K, in 3A is 0.926 W/m 2 K and in 4A is 3.417 w/m2k, corroborating that the double brick wall module with insulation complies with the maximum limits of the standard in walls and ceilings, but not in floors.en_US
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Andina del Cuscoes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/es_PE
dc.subjectTransmitancia térmicaes_PE
dc.subjectNorma EM. 110es_PE
dc.subjectEnvolventees_PE
dc.titleEvaluación comparativa de los valores de transmitancias térmicas de los módulos Sumaq Wasi en Ccatcca-Quispicanchi, según la norma em.110es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.grantorUniversidad Andina del Cusco. Facultad de Ingeniería y Arquitecturaes_PE
thesis.degree.disciplineIngeniería Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.00es_PE
renati.advisor.dni23707993
renati.advisor.orcidhttps://orcid.org/0000-0001-6891-6902es_PE
renati.author.dni72577418
renati.author.dni73891788
renati.discipline732016es_PE
renati.jurorCana Paullo, Hugo
renati.jurorArohuanca Sosa, Rode Luz
renati.jurorGil Rodríguez, Carmen Cecilia
renati.jurorÁlvarez Monterola, Walter Roberto
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess