Show simple item record

dc.contributor.advisorChacón Sánchez, Víctor
dc.contributor.authorCevallos Chachaima, Carlos Raúl
dc.contributor.authorNinancuro Calluco, Margareth Shirly
dc.date.accessioned2023-03-28T17:20:59Z
dc.date.available2023-03-28T17:20:59Z
dc.date.issued2021-12-28
dc.identifier.urihttps://hdl.handle.net/20.500.12557/5262
dc.description.abstractIncidencia (100% - presente en todas las muestras) y presencia (55.75% en cantidad promedio respecto al total de la muestra) del Grupo A, compuesto por concreto, ladrillos, tejas y materiales cerámicos de acuerdo al protocolo europeo, por lo tanto fue el material que se opta a utilizar, lo que a su vez genera que las muestras obtenidas del R.C.D. procesado estuviesen compuestas por concreto, ladrillos, tejas y materiales cerámicos. Seguidamente al ensayar el material obtenido por granulometría, se determinó que se tiene una proporción agregado grueso a agregado fino de 4 a 1 aproximadamente (80.13% a 19.80 exactamente) %, del cual se utiliza netamente el material considerado agregado fino por tratarse de un diseño de mortero. Finalmente, de los resultados de los ensayos clasificatorios para las unidades de R.C.D. se obtiene que las unidades elaboradas con árido R.C.D. y cemento portland tipo IP, cumplen con todo lo indicado por el R.N.E. Norma Técnica E.070 Albañilería, (2006), para Bloque tipo P(1): Para el ensayo de variación dimensional se obtienen los resultados: +0.30% y -0.30% para el largo, +0.77% y -0.70% para el ancho, +1.17% y -1.15% para la altura cumpliendo en todas las dimensiones con la norma técnica que indica una variación dimensional menor al 2.0% respecto a la dimensión siendo evaluada. Para el ensayo de alabeo se obtienen como resultados: para convexidad 3.00 mm y para concavidad 1.50mm, por lo que considera que el alabeo máximo con valor de 3.00 mm, cumpliendo con la norma técnica que indica un alabeo menor que 4.00mm. Para ensayo de resistencia a compresión característica a los 28 días se obtiene el resultado de 148.01 kg/cm2 para un grupo de 08 muestras, cumpliendo con la norma técnica que indica al menos 50.00 kg/cm2es_PE
dc.description.abstractThis research was oriented at evaluating the physical-mechanical behavior of masonry concrete units made from aggregate of construction and demolition waste (CDW) and Portland cement type IP manufactured in the city of Cusco, contrasting the results with what is required for the classification of masonry units by the R.N.E. Technical Standard E.070 Masonry, (2006) to determine the capacities and means in which these can be used. First, a survey was conducted to the public functionaries e material dispatchers whose functions were related to the management of the CDW, then CDW samples were classified by the European protocol and local Peruvian regulations (solid waste law, handling and management) both before and after being processed. Being that a mortar design was being used, it was decided to use the CDW aggregate as a replacement for the fine aggregate in the mixture, for which the CDW aggregate was tested for moisture content, granulometry, Atterberg limits, specific gravity and absorption percentage from the fine aggregate. The supplies and materials for the mortar (cement, water and aggregate) of the masonry units were studied and analyzed prior to the mix design. After the mix design, 18-hole block-type masonry units were made with approximate dimensions of 23.3, 13.6 and 8.6cm in length, width and height respectively, poured with the calculated dosage, a total of 53 units were made because 3 of them were damaged in the demolding process. Of these, half of the units were destined for destructive tests as follows: 12 units to be tested to compressive strength in units, 4 units for each age of 7, 14 and 28 days, 4 units to be tested to modulus of rupture for an age of 28 days and finally 9 to be tested in piles of 3 units for the age of 28 days to compressive strength in piles in a complementary way to this research. The other half was destined for the non-destructive tests of dimensional variation, warpage, weight, absorption, maximum absorption, suction and percentage of voids. The results of the surveys indicate that of the public functionaries 90.91% of the total have a basic level of knowledge regarding the CDW, while the material dispatchers have a level between null and minimum 73.33% and 26.67% of the total respectively. The results obtained from the unprocessed RCD material indicate that within the samples there was a higher incidence (100% - present in all samples) and presence (55.75% in average quantity from the total sample) from Group A, composed by concrete, bricks, tiles and ceramic materials according to the European protocol, therefore it was the material chosen to be used, which means that the samples obtained from the processed RCD were made up of concrete, bricks, tiles and ceramic materials. Subsequently, when testing the material obtained to granulometry, it was determined that there is a coarse aggregate to fine aggregate ratio of approximately 4 to 1 (80.13% to 19.8% exactly), of which the material considered fine aggregate is the chosen to be used because it is a mortar design. Finally, from the results of the qualifying tests for the CDW units, it is obtained that the units made with CDW aggregate and Portland cement type IP comply with everything indicated by the R.N.E. Technical Standard E.070 Masonry (2006), for Block type P( 1): For the dimensional variation test, the results: +0.30% and -0.30% for the length, +0.77% and -0.70% for the width, +1.17% and -1.15% for the height comply in all the dimensions with the Technical Standard that indicates a dimensional variation of less than 2.0% from the dimension being evaluated. For the warpage test, the following results are obtained: for convexity 3.00 mm and for concavity 1.50 mm, so it is considered that the maximum warpage is 3.00 mm, complying with the Technical Standard that indicates warping less than 4.00 mm. For the characteristic compressive strength test at 28 days, it is obtained a value of 148.01 kg/cm2 for a group of 08 samples, complying with the Technical Standard that indicates at least 50.00 kg/cm2en_US
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Andina del Cuscoes_PE
dc.rightsinfo:eu-repo/semantics/restrictedAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/es_PE
dc.subjectUnidad de albañileríaes_PE
dc.subjectManejo de residuoses_PE
dc.subjectConstrucción y demoliciónes_PE
dc.subjectReutilizaciónes_PE
dc.titleEvaluación del comportamiento Físico-mecánico de las unidades de ladrillo de concreto para albañilería, elaboradas con árido de residuos de construcción y demolición (R.C.D.) y cemento Pórtland tipo IP, fabricadas en la ciudad de Cuscoes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.grantorUniversidad Andina del Cusco. Facultad de Ingeniería y Arquitecturaes_PE
thesis.degree.disciplineIngeniería Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.00es_PE
renati.advisor.dni23807993
renati.advisor.orcidhttps://orcid.org/0000-0001-6891-6902es_PE
renati.author.dni47865359
renati.author.dni72427622
renati.discipline732016es_PE
renati.jurorAlvarez Espinoza, Jorge
renati.jurorChura Cortez, César Augusto
renati.jurorPezo Zegarra, Eliot
renati.jurorGil Rodríguez, Carmen Cecilia
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/restrictedAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/restrictedAccess