Show simple item record

dc.contributor.advisorSoto Florez, Heiner
dc.contributor.authorGarcía Rivas, Kevin Jordy
dc.date.accessioned2023-01-04T14:22:27Z
dc.date.available2023-01-04T14:22:27Z
dc.date.issued2022-06-23
dc.identifier.urihttps://hdl.handle.net/20.500.12557/5133
dc.description.abstractEl objetivo de esta investigación fue realizar un análisis comparativo de la respuesta sísmica y estructural del reservorio de Chinchero ubicado en el Distrito de Chinchero, Provincia de Urubamba y Departamento del Cusco, una estructura rectangular de hormigón armado del tipo contrafuerte, según Norma Norteamericana ACI 350.3 -06 “Diseño Sísmorresistente para Estructuras de Contención de Fluidos” frente a la norma peruana E.030 “diseño sísmico”. Teniendo en cuenta las propiedades hidrodinámicas del fluido en la estructura y su comportamiento ondulatorio en la superficie libre del fluido en caso de sismo. Para realizar este estudio se utilizó el modelo propuesto por G.W. Hausner aplicó el estándar ACI 350.3-06 para el análisis sísmico y utilizó el software SAP2000 para el modelado, a partir del cual se recopilaron los archivos de respuesta y posteriormente se analizaron. Los resultados de la investigación muestran que la fuerza axial, la fuerza cortante, el momento flector, el desplazamiento y el período de oscilación ocurren más en el bloque convectivo que en el bloque pulsado, considerando la Norma ACI 350.3-06 y la Norma Peruana E E.030 “Diseño Sismorresistente”. En resumen, según la norma ACI 350.306 comparada con la norma peruana E.030 “Diseño Sismorresistente”, la magnitud de los coeficientes de respuesta estructural y sísmica del reservorio de Chinchero en general no es mayor. El desarrollo de este estudio incluye los siguientes capítulos: Capítulo I: Planteamiento del problema Donde se ha descrito e identificado el problema, así como la justificación, viabilidad y trascendencia técnica y social; Objetivos, hipótesis, variables, alcances y limitaciones de esta tesis. Capítulo II: Marco teórico Presentan los antecedentes de la investigación actual, que se relaciona con el tema de investigación y también los aspectos teóricos relevantes, nos permite presentar completamente la base conceptual del tema de investigación. Los estudios anteriores incluyen métodos y procedimientos, entre otros. Capítulo III: Metodología La metodología de este estudio, que especifica el tipo, el nivel y los métodos del estudio, así como el diseño del estudio, la población y la muestra, las herramientas metodológicas o de recopilación de datos y las herramientas técnicas, los procedimientos de recopilación y análisis de datos y el diseño técnico o diagramas; indicar. del trabajo realizado. Capítulo VI: Resultados Se desarrolla un análisis comparativo de la norma ACI 350.3-06 del PNT “Diseño Sismorresistente” y se interpretan los resultados, obteniendo así respuestas a los objetivos propuestos, donde se encuentran tablas, figuras, datos, cálculos y análisis de datos entre otros. Capítulo V: Discusión Indica el contraste de los resultados con el marco teórico, interpretación de los resultados encontrados en la investigación, comentarios de la demostración de las hipótesis, las conclusiones, recomendaciones producto de la presenta investigación, referencias, anexos entre otros.es_PE
dc.description.abstractThe objective of this research was to carry out a comparative analysis of the seismic and structural response of the Chinchero reservoir located in the district of Chinchero, province of Urubamba and department of Cusco, a rectangular-shaped structure of supported-type reinforced concrete, according to the North American standard. ACI 350.3-06 "Seismic Design of Liquid Containing Structures" with respect to the Peruvian standard E.030 "Seismic-resistant Design". It takes into consideration the hydrodynamic characteristics of the liquid contained in the structure caused by the presence of an earthquake, as it has a wave behavior on the free surface of the fluid. To carry out this research, the model proposed by GW Housner was taken as a basis, applying it through the ACI 350.3-06 standard for seismic analysis, and for its modeling, the SAP2000 software was used, from which the response files were obtained which were later analyzed. The results of the investigation reveal that the axial forces, shear forces, bending moments, displacements and periods of vibration are more incident in the convective mass than for the impulsive mass, taking into account the ACI 350.3-06 standard and the Peruvian standard E. 030 "Earthquake resistant design". In conclusion, the magnitudes of the seismic and structural response parameters of the Chinchero reservoir in general are not greater, according to the ACI 350.3-06 standard with respect to that of the Peruvian standard E.030 “Seismic-resistant Design”. The development of this research is made up of the following chapters: Chapter I: Statement of the problem Where the problem was described and identified, as well as the technical, social, feasibility and relevance justifications; the objectives, hypotheses, variables, scope and limitations of this thesis. Chapter II: Theoretical framework Where the background of this research is presented, which are theses related to the subject of study and also the relevant theoretical aspects that allow us to provide the entire conceptual basis on said research topic, including methods and procedures, among others. Chapter III: Methodology Indicates the methodology of the present investigation, in which the type, level and method of the investigation are indicated, as well as the design of the investigation, the population and the sample, the methodological instruments or data collection. and engineering instruments, the collection procedures, data analysis and the engineering design or flowchart of the work carried out. Chapter VI: Results The comparative analysis of the ACI 350.3-06 standard with respect to the NTP "Earthquake Resistant Design" and interpretation of the results was developed, through which the answers of the proposed objectives were obtained, in these tables, figures, mathematical calculations, data analysis among others. Chapter V: Discussion Indicates the contrast of the results with the theoretical framework, interpretation of the results found in the investigation, comments on the demonstration of the hypotheses, the conclusions, recommendations resulting from the present investigation, references, annexes, among others.en_US
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Andina del Cuscoes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/es_PE
dc.subjectRespuesta sísmicaes_PE
dc.subjectRespuesta estructurales_PE
dc.subjectConcreto armadoes_PE
dc.subjectDiseño sísmicoes_PE
dc.subjectEstructuras contendoras de líquidoes_PE
dc.titleAnálisis comparativo de la respuesta sísmica y estructural del reservorio de Chinchero según la norma ACI 350 con respecto a la norma peruana E.030 diseño sismorresistente - Cusco 2020es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.grantorUniversidad Andina del Cusco. Facultad de Ingeniería y Arquitecturaes_PE
thesis.degree.disciplineIngeniería Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.00es_PE
renati.advisor.dni41089111
renati.advisor.orcidhttps://orcid.org/0000-0001-9675-9561es_PE
renati.author.dni47875640
renati.discipline732016es_PE
renati.jurorPezo Zegarra, Eliot
renati.jurorMamani Vargas, Elvis Yuri
renati.jurorMendoza Escalante, Camilo
renati.jurorRoman Villegas, Eigner
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess