Show simple item record

dc.contributor.advisorRomán Villegas, Eigner
dc.contributor.authorLaura Cansaya, José Luis
dc.contributor.authorRicalde Cotohuanca, Smith Stiwarth
dc.date.accessioned2022-12-22T21:27:22Z
dc.date.available2022-12-22T21:27:22Z
dc.date.issued2022-06-13
dc.identifier.urihttps://hdl.handle.net/20.500.12557/5054
dc.description.abstractEl objetivo de la presente investigación es determinar la capacidad portante del suelo en base a los resultados de los parámetros de resistencia cohesión (c) y ángulo de fricción interna (Φ) obtenidos por el ensayo de penetración estándar (SPT) y el ensayo triaxial tipo (UU) en condición no consolidado no drenado las cuales se realizaron en los laboratorios acreditados de Mecánica de Suelos y Geotecnia. GEOIN Geotecnia & Ingenieros E.I.R.L (Ensayo triaxial Puerto Maldonado) y GEOTEST Perú S.A.C (Ensayo de Penetración Estándar (SPT) - Cusco) cuyos resultados de estos ensayos fueron evaluados para encontrar la capacidad portante y admisible de dicho suelo usando la metodología que nos permita diferenciar los resultados en en base a los resultados obtenidos por la presente tesis al momento de iniciar una construcción de una edificación para la población de la APV Sol Naciente en alto Qosqo San Sebastián Cusco. Los parámetros de resistencia al corte “c” y “Φ” se obtuvieron a partir de los esfuerzos principales mayor y menor del ensayo Triaxial no consolidado no drenado (UU) ajustados con el criterio de falla lineal de Mohr-Coulomb. La “c” resulto ligeramente mayor en el ensayo Triaxial que el valor obtenido en el ensayo Penetración Estándar (SPT) así mismo el “Φ” resulto ser mayor en un aproximado de 54.94% de los 3 puntos de exploración, los resultados obtenidos de la capacidad admisible mediante las ecuaciones de TERZAGHI Y MERYERHOF resultaron valores altos por el método de Meyerhof, por ende, tomando los resultados obtenidos por el método de por Terzagui por ser el más conservador. Resultando para la calicata 1, Qadm. = 6.71 kg/cm2 en el ensayo SPT y Qadm. = 2.08 kg/cm2 en el ensayo Triaxial, para la calicata 2 Qadm. = 3.79 kg/cm2 en el ensayo SPT y Qadm. = 2.08 kg/cm2 en el ensayo Triaxial y finalmente para la calicata 3 un Qadm. = 4.08 kg/cm2 para el ensayo SPT y Qadm. = 2.18 kg/cm2 para el ensayo Triaxial, se encontró una diferencia significativa con respecto a los valores de “c” y “Φ”. Para el ensayo SPT en las calicatas la “c” = 0 kg/cm2 y “Φ” = 32°,29° y 30° respectivamente y para el ensayo Triaxial la “c” = 0.15; 0.18; 0.165 kg/cm2 y “Φ” = 17°,16° y 17°. Concluyendo que los resultados obtenidos por el ensayo Triaxial son más confiables que el ensayo de penetración estándar (SPT), porque son más precisos y no existe mucha diferencia de resultados obtenidos entre las calicatas estudiadas para el tipo de suelo analizado en la presente tesis.es_PE
dc.description.abstractThe objective of this research is to determine the bearing capacity of the soil based on the results of the parameters of resistance, cohesion (c) and internal friction angle (Φ) obtained by the standard penetration test (SPT) and the Triaxial type test. (UU) in unconsolidated condition not drained which were carried out in the accredited laboratories of Soil Mechanics and Geotechnics. GEOIN Geotecnia & Ingenieros EIRL (Triaxial Test - Puerto Maldonado) tests were evaluated to find the bearing and admissible capacity of said soil using the methodology that allows us differentiate the results in relation to the parameters obtained in the tests, thus generating a greater degree of reliability based on the results obtained by this thesis at the time of starting a construction of a building for the population of the APV Sol Naciente in Alto Qosqo San Sebastian - Cusco. The shear strength parameters "c" and "Φ" were obtained from the major and minor principal stresses of the unconsolidated undrained Triaxial test (UU) adjusted with the Mohr-Coulomb linear failure criterion. The “c” was slightly higher in the Triaxial test than the value obtained in the Standard Penetration test (SPT), likewise the “Φ” was found to be greater in an approximate of 54.94% of the 3 exploration points, the results obtained from the Admissible capacity using the TERZAGHI and MERYERHOF equations resulted in high values by the Meyerhof method, therefore, taking the results obtained by Terzagui's method as it is the most conservative. Resulting for pit 1, Qadm. = 6.71 kg / cm2 in the SPT and Qadm test. = 2.08 kg / cm2 in the Triaxial test, for the 2 Qadm test pit. = 3.79 kg / cm2 in the SPT and Qadm test. = 2.08 kg / cm2 in the Triaxial test and finally a Qadm for test pit 3. = 4.08 kg / cm2 for the SPT and Qadm test. = 2.18 kg / cm2 for the Triaxial test, a significant difference was found with respect to the values of "c" and "Φ". For the SPT test in the pits the “c” = 0 kg / cm2 and “Φ” = 32°, 29 ° and 30 ° respectively and for the Triaxial test the “c” = 0.15; 0.18; 0.165 kg / cm2 and "Φ" = 17 °, 16 ° and 17 °. Concluding that the results obtained by the Triaxial test are more reliable than the standard penetration test (SPT), because they are more precise and there is not much difference in the results obtained between the test pits studied for the type of soil studied in this thesis.en_US
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Andina del Cuscoes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/es_PE
dc.subjectCohesiónes_PE
dc.subjectAngulo de fricción internaes_PE
dc.subjectEnsayo SPTes_PE
dc.subjectEnsayo triaxiales_PE
dc.subjectCapacidad portantees_PE
dc.titleAnálisis Comparativo en la Determinación de la capacidad Portante del Suelo en base a la cohesión y el ángulo de fricción calculada por los ensayos de Penetración Estándar (SPT) in situ y Ensayo Triaxial en laboratorio en los terrenos de la A.P.V. sol Naciente en Alto Qosqo – San Sebastián - Cuscoes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.grantorUniversidad Andina del Cusco. Facultad de Ingeniería y Arquitecturaes_PE
thesis.degree.disciplineIngeniería Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es_PE
renati.advisor.dni23928061
renati.advisor.orcidhttps://orcid.org/0000-0003-2401-707Xes_PE
renati.author.dni46629114
renati.author.dni72667408
renati.discipline732016es_PE
renati.jurorChipana Molina, Yimmy Johan
renati.jurorMontesinos Cervantes, Alberto
renati.jurorGutierrez Vallejo, Heber Darwin
renati.jurorPeñalva Gallegos, Zandro
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
dc.description.lineadeinvestigacionCapacidad Portante del Sueloes_PE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess