dc.contributor.advisor | Merino Yépez, Robert Milton | |
dc.contributor.author | Amador Challco, Hugo Camilo | |
dc.date.accessioned | 2020-12-16T20:17:30Z | |
dc.date.available | 2020-12-16T20:17:30Z | |
dc.date.issued | 2019-12-26 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12557/3547 | |
dc.description.abstract | La investigación denominada “Determinación de la eficiencia de tratamiento de aguas
residuales en los sistemas del C.P. Huacoto y de la margen derecha del distrito de Saylla”;
cuantificará y determinará la eficiencia de los sistemas de tratamiento de aguas residuales de
cada poblado mencionado; según la determinación de la remoción de contaminantes conocidos
dentro de la Normatividad Peruana como los parámetros físicos, químicos y bacteriológicos de
vertimiento en un cuerpo receptor; además, se cuantificará la eficiencia para cada parámetro.
Para el cálculo mencionado se tendrá en cuenta las cargas de ingreso y salida de cada sistema
de tratamiento; el valor cuantitativo estará condicionada por los caudales de ingreso de cada
sistema, los tipos de estructuras y diseños hidráulicos; de acuerdo con el tipo de actividades de
cada poblado. En ambos sistemas se verificó que su vertimiento en el cuerpo receptor será en
la micro cuenca del rio de Huacoto y de la sub cuenca del río Huatanay.
También se verificará los factores metereológicos como la temperatura del ambiente y del
fluido; con la cual se determina los periodos de retención de las estructuras, pero más importante
el periodo de digestión de lodos.
La importancia de esta investigación se fundamenta en la recuperación de los recursos hídricos
en un tramo de la subcuenca del rio Huatanay desde el sector de Saylla y de la microcuenca de
Huacoto.
De la presente investigación se obtendrán valores cuantitativos, para verificar la eficiencia de
cada sistema; así como también recomendaciones para mejorar, o replantear nuevos métodos
de tratamiento de ser necesario. | es_PE |
dc.description.abstract | The research called “Determination of the efficiency of wastewater treatment in the systems of
the C.P. Huacoto and the right bank of the district of Saylla ”; quantify and determine the
efficiency of the wastewater treatment systems of each mentioned village; according to the
determination of the removal of pollutants known within Peruvian regulations as the physical,
chemical and bacteriological parameters of dumping in a receiving body; In addition, the
efficiency for each parameter will be quantified. For the calculation mentioned, the entry and
exit charges of each treatment system will be taken into account; The quantitative value will be
conditioned by the flow rates of each system, the types of structures and hydraulic designs;
according to the type of activities of each town. In both systems it was verified that its discharge
in the receiving body will be in the micro basin of the Huacoto River and the sub basin of the
Huatanay River.
Meteorological factors such as ambient and fluid temperature will also be verified; with which
the retention periods of the structures are determined, but more important the sludge digestion
period.
The importance of this research is based on the recovery of water resources in a section of the
sub-basin of the Huatanay river from the sector of Saylla and the microbasin of Huacoto.
From the present investigation quantitative values will be obtained, to verify the efficiency of
each system; as well as recommendations to improve, or rethink new treatment methods if
necessary. | en_US |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Andina del Cusco | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.5/pe/ | es_PE |
dc.source | Universidad Andina del Cusco | es_PE |
dc.source | Repositorio Institucional UAC | es_PE |
dc.subject | Aguas residuales | es_PE |
dc.subject | Estructuras | es_PE |
dc.subject | Vertimientos | es_PE |
dc.subject | Recursos hidricos | es_PE |
dc.title | Determinación de la eficiencia de tratamiento de aguas residuales en los sistemas del C.P. de Huacoto y de la margen derecha del distrito de Saylla | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.name | Ingeniero Civil | es_PE |
thesis.degree.grantor | Universidad Andina del Cusco. Facultad de Ingeniería y Arquitectura | es_PE |
thesis.degree.level | Titulo Profesional | es_PE |
thesis.degree.discipline | Ingeniería Civil | es_PE |