Show simple item record

dc.contributor.advisorConcha Rendón, Lorenzo Carlos
dc.contributor.authorUrbina Orosco, Dirce Milagros
dc.date.accessioned2018-04-04T21:11:02Z
dc.date.available2018-04-04T21:11:02Z
dc.date.issued2018-03-27
dc.identifier.urihttps://hdl.handle.net/20.500.12557/1439
dc.description.abstractIntroducción: La ictericia es causa frecuente de hospitalización en neonatos. El objetivo principal fue determinar la correlación entre la bilirrubina sérica total y la bilirrubina transcutánea en neonatos a término, en el Hospital Antonio Lorena, 2016-2017. Métodos: Es un estudio analítico, de correlación, prospectivo y transversal. Incluyo los recién nacidos a término, cuyas madres culminaron su gestación en el Hospital Antonio Lorena. En el análisis de datos se utilizó la R de Pearson (distribución normal), para las correlaciones. Se obtienen mediciones de desempeño de la prueba mediante la sensibilidad, especificidad, valor predictivo positivo y negativo. Los datos obtenidos se procesaron mediante el software estadístico “SPSS (versión 22)”. Resultados: La población estuvo conformada por 70 neonatos, los cuales 54% fueron varones y 46% mujeres, la edad promedio fue de 63 horas y la zona 3 de kramer fue predominante. El promedio de bilirrubina sérica fue 11.98 mg/dl, la bilirrubina transcutánea frontal de 13.45 mg/dl y la torácica de 13.35 mg/dl. Los índices de correlación de Pearson, tanto para la toma transcutánea frontal y torácica, fue de 0.84. La sensibilidad del bilirrubinómetro transcutáneo fue de 92%(frontal) y 100% (torácica), mientras que la especificidad fue menor en 74%. El valor predictivo positivo fue de 65%(frontal) y 67%(torácico), a diferencia del valor predictivo negativo con 92% (frontal) y 100% (torácico). El error estándar del bilirrubinómetro fue de +/- 1.47 (frontal) y de +/- 1.37 (torácico), con relación a la bilirrubina sérica. Conclusiones: Las mediciones transcutáneas tienen una correlación positiva con la bilirrubina sérica y detectaron la mayoría de neonatos con hiperbilirrubinemia, confirmando su utilidad como método de screening.es_PE
dc.description.abstractIntroduction: Jaundice is a frequent cause of hospitalization in neonates. The main objective was to determine the correlation between total serum bilirubin and transcutaneous bilirubin in term neonates, at the Hospital Antonio Lorena, 2016-2017. Methods: It is a descriptive, correlation, prospective and transversal study. I include full-term newborns, whose mothers completed their pregnancy at the Antonio Lorena Hospital. In the data analysis Pearson's R (normal distribution) was used for the correlations. Measurements of test performance are obtained by sensitivity, specificity, positive predictive value, negative predictive value. The data obtained were processed using the statistical software “SPSS (version 22)“. Results: The population consisted of 70 infants, of which 54% were males and 46% females, the average age was 63 hours and Kramer 3 was predominant. The Pearson correlation indexes, both for the frontal and thoracic transcutaneous take, were 0.84. The sensitivity of the transcutaneous bilirubinometer was 92% (frontal) and 100% (thoracic), while the specificity was lower in 74%. The positive predictive value was 65% (frontal) and 67% (thoracic) as opposed to the negative predictive value with 92% (frontal) and 100% (thoracic). The standard error of the bilirubinometer was +/- 1.47 (frontal) and +/- 1.37 (thoracic), in relation to serum bilirubin. Conclusions: Transcutaneous measurements have a positive correlation with serum bilirubin and detected the majority of neonates with hyperbilirubinemia, confirming its usefulness as a screening method.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Andina del Cuscoes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.5/pe/es_PE
dc.sourceUniversidad Andina del Cuscoes_PE
dc.sourceRepositorio Institucional - UACes_PE
dc.subjectIctericia neonatales_PE
dc.subjectBilirrubinaes_PE
dc.subjectHiperbilirrubinemiaes_PE
dc.titleCorrelación entre bilirrubina sérica total y bilirrubinometría transcutánea en neonatos a término, en el Hospital Antonio Lorena, 2016-2017.es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.nameMédico Cirujanoes_PE
thesis.degree.grantorUniversidad Andina del Cusco. Facultad de Ciencias de la Saludes_PE
thesis.degree.levelTitulo Profesionales_PE
thesis.degree.disciplineMedicina Humanaes_PE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess