dc.description.abstractSe realizó esta investigación utilizando una metodología experimental, que consistió en la elaboración de bloques de concreto no estructural de dimensiones comerciales 40cm.x20cm.x12cm. Los cuales fueron elaborados adicionando diferentes porcentajes de aserrín de aluminio por un tamaño máximo que fue la malla n° 8, estos porcentajes adicionados a los bloques de concreto fueron de 1.5%, 2.0%, 2.5% y 3.0% con respecto al peso promedio del bloque patrón. Durante el proceso de elaboración de los bloques de concreto se consideró para la fabricación, el proceso semi industrial en una bloquetera utilizando moldes metálicos instalados sobre una mesa vibratoria, y curadas por riego constante. Los bloques de concreto fueron sometidos a ensayos físico-mecánicos como son resistencia a la compresión, alabeo, variación dimensional, densidad y absorción para compararlos frente a las propiedades físico-mecánicas de un bloque patrón y frente a las exigencias mínimas de la Norma Técnica Peruana E.070. De acuerdo a los resultados obtenidos, en el capítulo IV se demostró que al adicionar en un 2.0% de aserrín de aluminio a los bloques de concreto su resistencia a la compresión llega a 51.53 kg/cm2 que es muy parecida a los del bloque patrón que llegan a 53.23kg/cm2, que al ser comparadas tienen una diferencia de 3.19%, por el contrario cuando se adiciono en un 1.5%, 2.5% y 3.0% de aserrín de aluminio, la resistencia a la compresión disminuyó en comparación al bloque patrón, llegando así la resistencia a la compresión a 44.20 kg/cm2, 32.72 kg/cm2, 30.79 kg/cm2 respectivamente. En cuanto a los ensayos de alabeo, densidad y absorción, se obtuvo resultados que se encuentran por debajo de lo establecido en la NTP E.070, pero en cuanto a la variación dimensional de los bloques, cumplieron con los parámetros exigidos exceptuando al ensayo hecho para su altura en cuanto al bloque patrón (0%) y al adicionado con un 1.5% que se obtuvo como resultado un 4.57% y 4.87% respectivamente; cabe resaltar que los parámetros especificados por la NTP E.070 para bloques de concreto no portante (NP) son; en cuanto a resistencia a compresión (f´b) es de 20 kg/cm2, para variación dimensional es de (±4) %, para alabeo es de 8mm y para absorción 15%.es_PE
dc.description.abstractThis research was carried out using an experimental methodology, which consisted in the production of non-structural concrete blocks with commercial dimensions 40cm x 20cm x 12cm. The concrete blocks were elaborated adding different percentages of aluminum sawdust for a maximum size that was the mesh n ° 8, these percentages added to the concrete blocks were of 1.5%, 2.0%, 2.5% and 3.0% about to the average weight of the block pattern. During the manufacturing process of the concrete blocks, the semi-industrial process was considered for manufacturing in a block using metal molds installed on a vibrating table, and cured by a constant irrigation. The concrete blocks were subjected to physical-mechanical tests such as resistance to compression, warping, dimensional variation, density and absorption to compare them against the physical-mechanical properties of a block pattern and against the minimum requirements of the Peruvian Technical Standard. E.070. According to the results obtained, in chapter IV it was demonstrated that when adding 2.0% of aluminum sawdust to concrete blocks, its compressive strength reaches 51.53 kg / cm2, which is very similar to those of the standard block. they reach 53.23kg / cm2, which when compared they have a difference of 3.19%, conversely when added in 1.5%, 2.5% and 3.0% of aluminum sawdust, the compressive strength decreased compared to the standard block , they reaching the compressive strength at 44.20 kg / cm2, 32.72 kg / cm2, 30.79 kg / cm2 respectively. Regarding the tests of warpage, density and absorption, results were obtained that are below the established in the NTP E.070, but in terms of the dimensional variation of the blocks, they met the required parameters except for the test done for its height in terms of the standard block (0%) and the one added with 1.5%, which resulted in 4.57% and 4.87% respectively; It should be noted that the parameters specified by NTP E.070 for non-bearing concrete blocks (NP) are; in terms of compressive strength (f'b) it is 20 kg / cm2, for dimensional variation it is (± 4)%, for warping it is 8mm and for absorption 15% up.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Andina del Cuscoes_PE
dc.rightsinfo:eu-repo/semantics/restrictedAccesses_PE
dc.sourceUniversidad Andina del Cuscoes_PE
dc.sourceRepositorio Institucional - UACes_PE
dc.subjectAserrín-Aluminioes_PE
dc.subjectConcreto no estructurales_PE
dc.subjectBloques de concretoes_PE
dc.titleInfluencia de la adición de aserrín de aluminio en porcentajes de 1.5%, 2%, 2.5% y 3% en las pruebas clasificatorias, densidad y absorción, de bloques de concreto no estructural de acuerdo a la norma E.070.es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.grantorUniversidad Andina del Cusco. Facultad de Ingeniería y Arquitecturaes_PE
thesis.degree.levelTitulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE