Show simple item record

dc.contributor.advisorQuispe Chauca, Jorge Luis
dc.contributor.authorGuzmán Manzano, Hernán Tomasini
dc.contributor.authorPuca Huamán, Jean Erick
dc.date.accessioned2023-12-21T21:23:59Z
dc.date.available2023-12-21T21:23:59Z
dc.date.issued2023-10-13
dc.identifier.urihttps://hdl.handle.net/20.500.12557/5993
dc.description.abstractEsta investigación tiene como principal propósito en contrastar las resistencias a la tracción “in vitro” de los sistemas adhesivos de quinta y séptima generación, en piezas dentales de personas, Cusco 2022. Se realizó un estudio Cuasiexperimental in vitro, empleando un mecanismo de experimentos CBR digital, mediante 30 premolares divididos en tres conjuntos de diez piezas cada uno, el primer grupo llamado A donde se utiliza el adhesivo de quinta generacion denominado ADPER SINGLE BOND 2 en el cual se realizó la adhesión en el esmalte y dentina; el siguiente grupo llamado B donde se utiliza el adhesivo de séptima generación denominado SINGLE BOND UNIVERSAL SCOTCHBOND en cual se realizó la prueba de adhesión en esmalte y dentina; el siguiente grupo llamado Grupo C, donde se utiliza el adhesivo de generación sétima denominada SINGLE BOND UNIVERSAL SCOTCHBOND, con el grabado ácido orto fosfórico previo a un 37% de concentración. La resistencia a la tracción fue analizada con la aplicación de la fuerza del mecanismo CBR digital, con 0.5 mm/min. de velocidad. Consiguiendo resultados en la unidad kilo newton que luego fue convertida a Newtons. La resistencia adhesiva a la tracción in vitro entre los sistemas adhesivos de quinta generación, séptima generación sin grabado ácido y séptima generación previo grabado ácido ortofosfórico al 37% en premolares humanos en esmalte y dentina, se evidencio un mayor esfuerzo-tracción del adhesivo de séptima generación previo grabado ácido en esmalte en relación al de quinta generación y séptima generación sin grabado ácido. Respecto a la dentina se evidencio un mayor esfuerzo-tracción del adhesivo de séptima generación previo grabado ácido en dentina en relación al de séptima generación sin grabado ácido y de quinta generación.es_PE
dc.description.abstractThe main purpose of this research is to contrast the "in vitro" tensile strength of the fifth and seventh generation adhesive systems, in dental pieces of people, Cusco 2022. An in vitro experimental study was carried out, using a mechanism of CBR experiments digital, by means of 30 premolars divided into three sets of ten pieces each, the first group called A where the fifth generation adhesive called ADPER SINGLE BOND 2 is used, in which the adhesion was carried out on the enamel and dentin; the next group called B where the seventh generation adhesive called SINGLE BOND UNIVERSAL SCOTCHBOND is used, in which the adhesion test on enamel and dentin was performed; the next group called Group C, where the seventh generation adhesive called SINGLE BOND UNIVERSAL SCOTCHBOND is used, with orthophosphoric acid etching prior to 37% concentration. The tensile strength was analyzed with the application of the force of the digital CBR mechanism, with 0.5 mm/min. of speed. Getting results in the kilo newton unit that was later converted to Newtons. The in vitro tensile adhesive strength between the fifth generation, seventh generation without acid etching and previous seventh generation 37% orthophosphoric acid etched adhesive systems in human premolars in enamel and dentin, showed a higher stress-traction of the seventh grade adhesive. previous generation enamel acid etching in relation to the fifth generation and seventh generation without acid etching. With respect to dentin, a greater stress-traction of the previous seventh-generation acid- etched adhesive in dentin was evidenced in relation to the seventh-generation adhesive without acid-etching and fifth-generation adhesive.en_US
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Andina del Cuscoes_PE
dc.rightsinfo:eu-repo/semantics/restrictedAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/es_PE
dc.subjectResistenciaes_PE
dc.subjectTracciónes_PE
dc.subjectPremolareses_PE
dc.subjectSistema adhesivoes_PE
dc.titleComparación in vitro de la resistencia a la tracción de los sistemas adhesivos de quinta y séptima generación en premolares humanos, Cusco-2022.es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.nameCirujano Dentistaes_PE
thesis.degree.grantorUniversidad Andina del Cusco. Facultad de Ciencias de la Saludes_PE
thesis.degree.disciplineEstomatologíaes_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.14es_PE
renati.advisor.dni40975702
renati.advisor.orcidhttps://orcid.org/0000-0002-1299-7907es_PE
renati.author.dni70760537
renati.author.dni74141106
renati.discipline911016es_PE
renati.jurorArenas Fernández Dávila, Jesús Alejandro
renati.jurorRivera Medina, Edgardo Guillermo
renati.jurorCorzo Palomo, Erika Eleana
renati.jurorGutierrez Gayoso, Giovanna
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE


Files in this item

Thumbnail
Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/restrictedAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/restrictedAccess