dc.contributor.advisor | Soto Bringas, Rosario Isabel | |
dc.contributor.author | Condori Mamani, Bernardo | |
dc.date.accessioned | 2021-01-08T15:14:59Z | |
dc.date.available | 2021-01-08T15:14:59Z | |
dc.date.issued | 2019-12-20 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12557/3560 | |
dc.description.abstract | Objetivo: Es determinar la biometría fetal en gestantes a término en altura del puesto de
salud Mariano Melgar – Puno setiembre a diciembre 2017. Material y Métodos: Se
realizó recolección de datos a un total de 100 gestantes a término, el instrumento consta
de cuatro partes: datos generales de la gestante, datos gineco-obstétricos de embarazo
actual, datos ecográficos obstétricos y observaciones con conclusiones de biometría fetal.
El diseño de estudio es de tipo observacional, prospectivo y transversal; segundo nivel de
investigación y corresponde a la línea de investigación de salud materna y reproductiva.
Resultados: Del total de 100 gestantes, 25 pertenecen a gestantes de 37 semanas de los
cuales 72% están en P50 con respecto a diámetro biparietal, 80% están en P50 de
circunferencia cefálica, 84% está en P50 de circunferencia abdominal y 76% en P50 de
longitud femoral y finalmente el 48% corresponde a gestación de 37.3 a 37.4. Con
respecto a 38 semanas 25 gestantes de los cuales 84% están en P50 con respecto a
diámetro biparietal, circunferencia cefálica, circunferencia abdominal y longitud femoral
y finalmente el 40% corresponde a gestación de 38.3 a 38.4. Con respecto a 39 semanas
28 gestantes de los cuales 86% están en P50 con respecto a diámetro biparietal, 79%
están en P50 de circunferencia cefálica, 75% está en P50 de circunferencia abdominal y
82% en P50 de longitud femoral y finalmente el 82% corresponde a gestación de 39 a
39.2 y finalmente 22 gestantes a 40 semanas de los cuales 95% están en P50 con respecto
a diámetro biparietal, circunferencia cefálica, circunferencia abdominal y 91% en P50 de
longitud femoral y finalmente el 68% corresponde a gestación de 40 a 40.2 semanas.
Conclusiones: Se determinó que la biometría fetal no muestra diferencia en gestantes a
término en altura del puesto de salud de Mariano Melgar – Puno setiembre a diciembre
2017. | es_PE |
dc.description.abstract | Objective: To determine the fetal biometry in full-term pregnant women at the Mariano
Melgar-Puno health post from September to December 2017. Material and Methods: A
survey was conducted on a total of 100 pregnant women at term, the instrument has four
parts: general data of the pregnant woman, gynecological-obstetric data of current
pregnancy, obstetric ultrasound data and observations with conclusions of fetal biometry.
The study design is observational, prospective and transversal; second level of research
and corresponds to the research line of maternal and reproductive health. Results: Of the
total of 100 pregnant women, 25 belong to pregnant women of 37 weeks of which 72%
are in P50 with respect to biparietal diameter, 80% are in P50 of cephalic circumference,
84% are in P50 of abdominal circumference and 76% in P50 of femoral length and finally
48% corresponds to gestation from 37.3 to 37.4. With regard to 38 weeks 25 pregnant
women of which 84% are in P50 with respect to biparietal diameter, head circumference,
abdominal circumference and femoral length and finally 40% corresponds to gestation
from 38.3 to 38.4. With regard to 39 weeks 28 pregnant women of whom 86% are in P50
with respect to biparietal diameter, 79% are in P50 of cephalic circumference, 75% in
P50 of abdominal circumference and 82% in P50 of femoral length and finally 82 %
corresponds to gestation of 39 to 39.2 and finally 22 pregnant women to 40 weeks of
which 95% are in P50 with respect to biparietal diameter, head circumference, abdominal
circumference and 91% in P50 of femoral length and finally 68% corresponds to gestation
from 40 to 40.2 weeks. Conclusions: It was determined that fetal biometry does not show
a difference in term pregnants in height of the health post of Mariano Melgar - Puno from
September to December 2017. | en_US |
dc.description.uri | Tesis de segunda especialidad | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Andina del Cusco | es_PE |
dc.rights | info:eu-repo/semantics/restrictedAccess | es_PE |
dc.source | Universidad Andina del Cusco | es_PE |
dc.source | Repositorio Institucional UAC | es_PE |
dc.subject | Biometría fetal | es_PE |
dc.subject | Diámetro biparietal | es_PE |
dc.subject | Circunferencia cefálica | es_PE |
dc.subject | Circunferencia abdominal | es_PE |
dc.subject | Longitud femoral | es_PE |
dc.title | Biometría fetal en gestantes a término en altura Puesto de Salud Mariano Melgar - Puno setiembre a diciembre 2017 | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.name | Ecografía Obstétrica y Monitoreo Fetal | es_PE |
thesis.degree.grantor | Universidad Andina del Cusco. Facultad de Ciencias de Salud. | es_PE |
thesis.degree.level | Titulo de Segunda Especialidad | es_PE |
thesis.degree.discipline | Obstetricia | es_PE |