Show simple item record

dc.contributor.advisorDelgado Salazar, William Ronald
dc.contributor.authorLlamocca Tupayachi, Marlie
dc.contributor.authorPaliza Chino, Diana Soledad
dc.date.accessioned2020-12-16T17:40:28Z
dc.date.available2020-12-16T17:40:28Z
dc.date.issued2020-02-17
dc.identifier.urihttps://hdl.handle.net/20.500.12557/3545
dc.description.abstractEsta investigación se sitúa en la Ciudad del Cusco y pretende evaluar la eficiencia del proceso de filtración de la PTAP Santa Ana – Cusco, que abastece a una población de 124246 habitantes este se ajuste con mayor detalle a lo establecido por el Reglamento Nacional de Edificaciones (RNE) en la norma OS.020 Plantas de Tratamiento de Agua para Consumo Humano, para ello estos valores fueron calculados de acuerdo con los datos de turbiedad del agua obtenidos antes y después de los filtros. Para determinar la eficiencia del proceso de filtración se tomaron en cuenta los datos de turbiedad dentro, antes y a la salida de los filtros. Para poder tener más conocimiento del proceso de filtración se utilizó documentos de la PTAP que fueron brindados por la EPS SEDACUSCO S.A. Los meses elegidos fueron enero, febrero, marzo, abril, mayo y junio del año 2019, año en el que se realizó la investigación, estos meses fueron representativos de acuerdo con el estado meteorológico de la ciudad del Cusco. Con los datos obtenidos de la planta se evalúa el porcentaje de eficiencia mediante la fórmula de eficiencia proporcionada por el Reglamento de Sector de Agua Potable y Saneamiento Básico RAS 2000 de la norma colombiana, estos resultados serán evaluados y comparados con los parámetros proporcionados en la norma peruana OS.020 del Reglamento Nacional de edificaciones. El resultado de esta evaluación nos proporciona que, durante los meses con abundante precipitación pluvial, la PTAP Santa Ana – Cusco no cumple con los parámetros establecidos por la norma debido a que la turbiedad es abundante, por consecuencia la eficiencia del filtro se reduce. En conclusión, los valores obtenidos de eficiencia varían de acuerdo con el estado meteorológico de la región del Cusco.es_PE
dc.description.abstractThis research is located in the city of Cusco and aims to identify the efficiency of the filtration process in the Treatment Plant of Santa Ana – Cusco, which fits in more detail to what is established by the National Building Regulation (RNE) in the estándar OS.020 Water Treatment Plants fot Human Comsumption, for this purpose these values were calculated according to the turbity data obtained form the water before and after the filters. To determinate the efficiency of the filtration process, turbity data whithin the filters were taken into account, before entering the filters, when leaving the filters – befores entering the reservoir. In order to have more knowledge of the operation and the filters operation and the filtration process, the funcionality and operation documents the PTAP were used, which were provided by the EPS SEDACUSCO. The months chosen within the investigation were representative acconrding to the meteorological state of Cusco. With the data obtained from the plant, the percentage of efficiency, that has been evaluated by a formula provided by the regulation of the RAS 2000 Drinking wáter and Basic Sanitation Sector Regulation, these results will be evaluated and compared with the parameters provided in the OS.020 and the aforementioned RAS 2000. The results of this evaluation provides us that, during the months with abundant rainfall, the Santa Ana – Cusco PTAP does not meet the parameters established by the estándar bacause the turbidity is abundant so the efficiency of the filter is reduced. In conclusión, the values obtained from the data processing vary according to the meteorological state of Cusco.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Andina del Cuscoes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.5/pe/es_PE
dc.sourceUniversidad Andina del Cuscoes_PE
dc.sourceRepositorio Institucional UACes_PE
dc.subjectEficienciaes_PE
dc.subjectFiltroses_PE
dc.subjectTurbiedad del aguaes_PE
dc.subjectPlanta de tratamientoes_PE
dc.subjectAgua potablees_PE
dc.titleEvaluación de la eficiencia del proceso de filtración de la planta de tratamiento de agua potable Santa Ana - Cusco aplicando la norma OS.020 y el Reglamento Técnico del Sector de agua Potable y Saneamiento Básico RAS 2000es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.grantorUniversidad Andina del Cusco. Facultad de Ingeniería y Arquitecturaes_PE
thesis.degree.levelTitulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01en_US
renati.advisor.dni24001899
renati.author.dni71834593
renati.author.dni70570383
renati.discipline732016
renati.jurorLuna Loayza, Carlos
renati.jurorMosqueira Lovon, Carlos Alberto
renati.jurorChura Cortez, Cesar Augusto
renati.jurorAlvarez Espinoza, Jorge
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess