Show simple item record

dc.contributor.advisorSoto Florez, Heiner
dc.contributor.authorBustamante Lazarte, Vania Cristell
dc.contributor.authorFernández Sánchez, Verónica
dc.date.accessioned2017-12-14T13:55:18Z
dc.date.available2017-12-14T13:55:18Z
dc.date.issued2017-09-29
dc.identifier.urihttps://hdl.handle.net/20.500.12557/1162
dc.description.abstractLa presente investigación tiene el principal objetivo de analizar comparativamente el módulo de elasticidad y el módulo de rotura de un concreto patrón f’c = 210 kg/cm2 comparado con un concreto f’c = 210kg/cm2 reemplazado con fibra de acero (2.48% del agregado fino) y fibra de ralladura de caucho al agregado fino en diferentes porcentajes y conocer si esta dosificación presenta mejor comportamiento comparado con un concreto normal. En este caso se usó fibra de ralladura de caucho reciclado (neumáticos) con variaciones de 3%, 5% y 7% del peso del agregado fino y fibra de acero trefilado LHO 45/35, se realizó 120 muestras cumpliendo con la norma NTP 339.033, 60 briquetas cilíndricas de 15x30cm que fueron sometidas a ensayo de compresión para poder hallar el módulo de elasticidad y 60 viguetas de 15x15x50 para ser ensayada a flexión y poder hallar el módulo de rotura. En base a los resultados obtenidos para el módulo de elasticidad se comparó el concreto patrón con el concreto reemplazado con fibras de ralladura de caucho y fibra de acero se observó que existe una disminución con respecto al concreto patrón. Sin embargo, para los datos obtenidos para el módulo de rotura, se verificó un incremento para la variación del 3% de caucho, mostrando mejores resultados que el concreto patrón y validando de esa manera nuestra tercera hipótesis específica y cumplió el objetivo de nuestra investigaciónes_PE
dc.description.abstractThis research has the main objective to comparatively analyze the modulus of elasticity and the modulus of rupture of a standard concrete f'c = 210 kg/cm2 compared to concrete f'c = 210 kg / cm2 had been replaced with steel fiber (2.48%) and fiber of rubber to the fine aggregate in different percentages so we know if this dosage of concrete presents a better behavior compared to a standard concrete. In this investigation we used recycled rubber (tires) with replacement of 3%, 5% and 7% of the weight of fine aggregate and drawn steel fiber LHO 45/35; 120 samples were made in compliance with the NTP 339.033, 60 cylindrical briquettes of 15x30cm that were tested to compression to find the modulus of elasticity and 60 beams of 15x15x50cm tested in flexion so we could found the modulus of rupture. Based on the results of the modulus of elasticity we compared the standard concrete with the concrete replaced with fibers of rubber and steel fiber we saw the decrease with respect to the concrete standard. However, for the data obtained of the rupture modulus, an increase for the 3% rubber variation was verified, showing better results than the standard concrete so we validated our 3rd specific hypothesis and fulfilling the objective of our investigation.en_US
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Andina del Cuscoes_PE
dc.rightsinfo:eu-repo/semantics/restrictedAccesses_PE
dc.sourceUniversidad Andina del Cuscoes_PE
dc.sourceRepositorio Institucional - UACes_PE
dc.subjectConcretoes_PE
dc.subjectCauchoes_PE
dc.subjectAcero trefiladoes_PE
dc.subjectMòdulo-Elasticidades_PE
dc.titleAnálisis comparativo del módulo de elasticidad y modulo de rotura de un concreto patrón f`c=210 y un concreto f`c=210 kg/cm2 reemplazado con fibras de ralladura de caucho y fibra de acero al agregado fino, Cusco 2017.es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.grantorUniversidad Andina del Cusco. Facultad de Ingeniería y Arquitecturaes_PE
thesis.degree.levelTitulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record